RC3000 Antenna Controller

Chapter 3

Detailed Operation

3.3.2.9 Fluxgate Calibration Procedure

The fluxgate compass calibration procedure is performed to compensate for sources of hard and soft iron magnetic deviations from the host mount. Review the discussion on the importance of selecting a suitable site for performing the calibration in section 2.4.1.

NOTE: the fluxgate compass must be in a level orientation to perform a good calibration.

The user is prompted to hit the Enter key to begin the procedure. If the user is not confident that the location for calibration is adequate or does not have the ability to move the mount, the procedure may be exited by hitting the Mode key.

8 PT COMPASS CAL

<ENTER> TO BEGIN CAL <MODE> TO EXIT

Fields to show the quality of the calibration are displayed. Until the calibration is finished, an “*” is displayed. Following successful completion of the procedure, the scores reported by the fluxgate compass will be displayed. Each procedure has unique messages for prompting the user on how to proceed.

MOVE TO INITIAL HEADING & <ENTER>

ROTATE 45 DEG.(START + 45/90/135/180/225/270/315) & <ENTER>

The eight point calibration procedure requires the mount to be moved 45 degrees at a time. The first prompt asks for the mount to be moved to an initial position. After moving to the requested position, the user must let the compass know by pressing the Enter key. These steps will be repeated for 45, 90, 135, 180, 225, 270 and 315 degrees.

The requirement is not that the mount be initially placed at a true heading of 0 degrees initially. Rather the value indicates the number of degrees from the starting orientation. Also the movement each time needs only be +/- 15 degrees from the requested 45 each time. Marking out eight equidistant bearings before the procedure is performed may be beneficial.

MOVEMENT MAY STOP-PERFORMING CALCULATION

When the calibration has collected enough data, the “movement may be stopped” message is displayed. Do not mode out of calibration until the calibration finished message is displayed.

CALIBRATION FINISHED,<MODE> TO EXIT

This message indicates the fluxgate has finished performing its calibration calculations. At this time new calibration scores are displayed.

8 PT COMPASS CAL

 

CAL QUALITY:8

(0-9,>6 PREFFERRED)

MAG ENVIRON:7

(0-9,>5 PREFFERRED)

CALIBRATION FINISHED, <MODE> TO EXIT

COMM ERROR

At any time during the calibration procedures the RC3000 detects an abnormal response from the fluxgate, the communication error message is displayed. Exit the procedure by pressing the mode key.

126