HP Serviceguard Metrocluster manual #### #### Clusterevent

Models: Serviceguard Metrocluster

1 151
Download 151 pages 11.74 Kb
Page 120
Image 120

#### ####

 

 

 

 

####

#### ####

CLUSTER_ALERT

<min> MINUTES <sec> SECONDS

####

#### #### Delay before the software issues an alert

####

#### #### notification about the cluster event.

####

#### ####

 

 

 

 

####

#### #### CLUSTER_ALARM

<min> MINUTES <sec> SECONDS

####

#### #### Delay before the software issues an alarm

####

#### #### notification about the cluster event and

####

#### #### enables the cmrecovercl(1m) command for

####

#### #### immediate execution.

 

####

#### ####

NOTIFICATION

<type>

####

#### ####

<message>

 

 

 

####

#### #### A string value which is sent from the monitoring

####

#### #### cluster for a given event to a specified

####

#### #### destination. The <message>, which can be no more

####

#### #### than 170 characters, is also appended to the

####

#### #### /var/opt/resmon/log/cc/eventlog file on the

####

#### #### monitoring node in the cluster where the event

####

#### #### was detected.

 

 

 

####

#### ####

 

 

 

 

####

#### ####

 

 

 

 

####

#### #### Example:

 

 

 

####

#### ####

 

 

 

 

####

#### #### CLUSTER_EVENT

westcoast/UNREACHABLE

####

#### #### MONITORING_CLUSTER

eastcoast

####

#### #### CLUSTER_ALERT

5 MINUTES

####

#### #### NOTIFICATION

EMAIL

admin@primary.site

####

#### #### "westcoast status unknown for 5 min. Call

####

#### #### secondary site."

 

 

####

#### #### NOTIFICATION EMAIL

 

admin@secondary.site

####

#### #### "Call primary admin. (555) 555-6666."

####

#### ####

 

 

 

 

####

#### #### CLUSTER_ALERT

10 MINUTES

####

#### #### NOTIFICATION

EMAIL

admin@primary.site

####

#### #### "westcoast status unknown for 10 min. Call

####

#### #### secondary site."

 

 

####

#### #### NOTIFICATION

EMAIL

admin@secondary.site

####

#### #### "Call primary admin. (555) 555-6666."

####

#### #### NOTIFICATION

CONSOLE

####

#### #### "Cluster ALERT:

westcoast not responding."

####

#### ####

 

 

 

 

####

#### #### CLUSTER_ALARM

15 MINUTES

####

#### #### NOTIFICATION

EMAIL

admin@primary.site

####

#### #### "westcoast status unknown for 15 min. Takeover

####

#### #### advised."

 

 

 

####

#### #### NOTIFICATION

EMAIL

admin@secondary.site

####

#### ####

"westcoast still not responding. Use

####

#### #### cmrecovercl command."

 

####

#### #### NOTIFICATION

CONSOLE

####

#### #### "Cluster ALARM: Issue cmrecovercl command to take

####

#### #### over "westcoast."

 

 

####

#### ####

 

 

 

 

####

#### ####

CLUSTER_EVENT

 

westcoast/UP

####

#### #### MONITORING_CLUSTER

eastcoast

####

#### #### CLUSTER_ALERT

0 MINUTES

####

#### #### NOTIFICATION

EMAIL

admin@secondary.site

####

#### #### "Cluster westcoast is up."

####

#### ####

 

 

 

 

####

#### #### CLUSTER_EVENT

westcoast/DOWN

####

#### #### MONITORING_CLUSTER

 

eastcoast

####

#### #### CLUSTER_ALERT

0 MINUTES

####

#### #### NOTIFICATION

EMAIL

admin@secondary.site

####

#### #### "Cluster westcoast is down."

####

#### ####

 

 

 

 

####

#### #### CLUSTER_EVENT

westcoast/ERROR

####

120 Sample Continentalclusters ASCII configuration file

Page 120