HP Serviceguard Metrocluster manual Datasenderpackage clustername/packagename

Models: Serviceguard Metrocluster

1 151
Download 151 pages 11.74 Kb
Page 83
Image 83

The parameter consists of a pair of names: the name of the cluster that receives the data to be replicated (usually the Recovery Cluster) as defined in the Serviceguard cluster configuration ASCII file, followed by a slash (“/”), followed by the name of the data replication receiver package as defined in the Serviceguard package configuration ASCII file. Some replication software might only have a receiver package as separate package because the sender package is built into the application.

DATA_SENDER_PACKAGE clustername/packagename

This variable is only used if the data replication is carried out by a separate software application that must be kept highly available. If the replication software uses a sender process, you include this variable in the configuration file. Maximum size is 80 characters.

The parameter consists of a pair of names: the name of the cluster that sends the data to be replicated (usually the Primary Cluster) as defined in the Serviceguard cluster configuration ASCII file, followed by a slash (“/”), followed by the name of the data replication sender package as defined in the Serviceguard package configuration ASCII file. Some replication software might only have a receiver package as separate package because the sender package is built into the application.

MONITOR_INTERVAL n

The interval, in seconds, that the Continentalclusters monitor polls the cluster, nodes, and packages to see if the status has changed. This number must be an integer. The minimum value is 30 seconds, the default is 60 seconds, and the maximum is 300 seconds (5 minutes).

MONITOR_PACKAGE_NAME

This is the name of the Serviceguard package containing

packagename

the Continentalclusters monitor. Maximum size is 31 bytes.

MONITORING_CLUSTER Name

 

This is name of the cluster that polls the cluster named in the

CLUSTER_EVENT and sends notification. Maximum length is 31 bytes.

NODE_NAME nodename This is the unqualified node name as defined in the DNS name server configuration. Maximum size is 31 bytes.

NOTIFICATION Destination This is a destination and message associated with a specific

MessageCLUSTER_ALERT or CLUSTER_ALARM. The maximum size of the message string is 170 characters including the quotation marks. The message string must be entered on a separate single line in the configuration file.

The following destinations are acceptable:

CONSOLE - write the specified message to the console.

EMAIL Address - send the specified message to an email address. You can use an email address provided by a paging service to set up automatic paging. Consult your pager service provider for details.

OPC Level - send the specified message to OpenView IT/Operations. The Level can be 8 (normal), 16 (warning), 64 (minor), 128 (major), or 32 (critical).

SNMP Level - send the specified message as an SNMP trap. The Level can be 1 (normal), 2 (warning), 3 (minor), 4 (major), or 5 (critical).

SYSLOG - Append a notice of the specified message to the /var/adm/syslog/syslog.log file. Note