value is an empty string, this will indicate to the monitor that

 

no email notifications sent.

MON_NOTIFICATION_SYSLOG

(Default = 0)

 

This parameter defines whether the monitor will send

 

notifications to the syslog file. When the parameter is set to

 

0, the monitor will NOT send notifications to the syslog file.

 

When the parameter is set to 1, the monitor will send

 

notifications to the syslog file. If the parameter is not defined

 

(commented out), the default value is 0.

MON_NOTIFICATION_CONSOLE

(Default = 0)

 

This parameter defines whether the monitor will send console

 

notifications. When the parameter is set to 0, the monitor

 

will NOT send console notifications. When the parameter

 

is set to 1, the monitor will send console notifications. If the

 

parameter is not defined (commented out), the default value

 

is 0.

AUTO_RESYNC

This parameter defines the pre-defined resynchronization

 

actions that the monitor can perform when the package is

 

on the PVOL side and the monitor detects the Continuous

 

Access data replication link is down. If the variable is not

 

defined or commented, the default value of 0 is used.

 

Values:

 

0 — (Default) When the parameter is set to 0, the monitor

 

will not perform any resynchronization actions.

 

1 — When the parameter is set to 1 and the data replication

 

link is down, the monitor will split the remote BC (if

 

configured) and try to resynchronize the device. Until the

 

resynchronization starts, the monitor will try to resynchronize

 

every polling interval. Once the device group has been

 

completely resynchronized, the monitor will resynchronize

 

the remote BC.

 

2 – When the parameter is set to 2 and the data replication

 

link is down, the monitor will only try to perform

 

resynchronization if a file named MON_RESYNC exists in the

 

package directory (PKGDIR). The monitor will not perform

 

any operations to the remote BC (that is, split and

 

resynchronize the remote BC). Therefore, this setting is used

 

when you want to manage the remote BC

Package Attributes for Continentalcluster with Continuous Access EVA

This appendix lists all Package Attributes for Metrocluster with Continuous Access EVA. HP recommends that you use the default settings for most of these variables, so exercise caution when modifying them:

CLUSTER_TYPE

This parameter defines the clustering environment in which

 

the script is used. You must set this to “metro” if this is a

 

Metrocluster environment and “continental” if this is a

 

Continentalclusters environment. A type of “metro” is

 

supported only when the HP Metrocluster product is installed.

 

A type of “continental” is supported only when the HP

 

Continentalclusters product is installed.

DTS PKG DIR

If the package is a legacy package, this variable contains

 

the full path name of the package directory. If the package

 

is a modular package, this variable contains the full path

Package Attributes for Continentalcluster with Continuous Access EVA 95

Page 95
Image 95
HP Serviceguard Metrocluster manual Monnotificationsyslog, Monnotificationconsole, Autoresync