E Package attributes

Package Attributes for Continentalcluster with Continuous Access for P9000 and XP

This appendix lists all Package Attributes for Metrocluster with Continuous Access for P9000 and XP. HP recommends that you use the default settings for most of these variables, so exercise caution when modifying them:

AUTO_FENCEDATA_SPLIT

(Default = 1)

 

This parameter applies only when the fence level is set to

 

DATA, which will cause the application to fail if the

 

Continuous Access link fails or if the remote site fails.

 

Values:

 

0 – Do NOT startup the package at the primary site. Require

 

user intervention to either fix the hardware problem or to

 

force the package to start on this node by creating the

 

FORCEFLAG file. Use this value to ensure that the SVOL

 

data is always current with the trade-off of long application

 

downtime while the Continuous Access link and/or the

 

remote site are being repaired.

 

1 – (DEFAULT) Startup the package at the primary site.

 

Request the local disk array to automatically split itself from

 

the remote array. This will ensure that the application able

 

to startup at the primary site without having to fix the

 

hardware problems immediately. Note that the new data

 

written on the PVOL will not be remotely protected and the

 

data on SVOL non-current. When the Continuous Access

 

link and/or the remote site is repaired, you must manually

 

use the command “pairresync” to re-join the PVOL and

 

SVOL. Until that command successfully completes, the PVOL

 

will NOT be remotely protected and the SVOL data will not

 

be current. Use this value to minimize the down time of the

 

application with the trade-off of having to manually

 

resynchronize the pairs while the application is running at

 

the primary site.

 

If the package has been configured for a three data center

 

environment, this parameter is applicable only when the

 

package is attempting to start up in either the primary (DC1)

 

or secondary (DC2) data center. This parameter is not

 

relevant in the recovery cluster or the third data center. Use

 

this parameter’s default value in the third data center.

AUTO_NONCURDATA

(Default = 0)

 

This parameter applies when the package is starting up with

 

possible non-current data under certain Continuous Access

 

pair states. During failover, this parameter will apply when

 

the SVOL is in the PAIR or PFUL state and the PVOL side is

 

in the PSUE, EX_ENORMT, EX_CMDIOE or PAIR (for

 

Continuous Access Journal) state. During failback, this

 

parameter will apply when the PVOL is in the PSUS state

 

and the SVOL is in the EX_ENORMT or EX_CMDIOE state.

 

When starting the package in any of the above states, you

 

run the risk of losing data.

 

Values:

88 Package attributes