SmartConnect User’s Guide

ACL Metering Settings

The following table describes the ACL metering configuration controls:

Table 9-5ACL Metering Configuration Fields

Field

Description

 

 

Committed rate

Configures the committed rate, in Kilobits per second. The committed

 

rate must be a multiple of 64.

 

 

Maximum burst size

Configures the maximum burst size, in Kilobits. Enter one of the fol-

 

lowing values for mbsize: 32, 64, 128, 256, 512, 1024, 2048, 4096

 

 

Set out-of-profile Drop or

Configures the ACL Meter to either drop or pass out-of-profile traffic.

Pass

 

 

 

Enable

Enables or disables the ACL meter.

 

 

ACL Remark Control

The following table describes the ACL remarking configuration controls:

Table 9-6ACL Remarking Configuration Fields

Field

Description

 

 

Set in-profile update DSCP

Enables or disables DiffServ Code Point (DSCP) updates for In-Profile

enable

packets.

 

 

Set in-profile update DSCP

Sets the DSCP of In-Profile packets to the selected value.

 

 

Set out-of-profile update

Enables or disables DSCP updates for Out-of-Profile packets.

DSCP enable

 

 

 

Set out-of-profile update

Sets the DSCP of Out-of-Profile packets to the selected value.

DSCP

 

 

 

See also:

„“Virtual Switch Groups Membership” on page 97

„“Access Control List Sets” on page 111

110 „ Chapter 9: Switch Policies

BMD00082, February 2009

Page 112
Image 112