SmartConnect User’s Guide
Using the Browser-Based Interface
Use the management system to access the switch through a Web session. Choose menu I/O Module Tasks > Configuration from the navigation pane on the left. Select a bay number and click Advanced Configuration > Start Telnet/Web Session > Start Web Session. A Web browser window opens a connection to the VSE SmartConnect software interface on the switch.
The switch’s
Access via HTTP
BBI access is enabled by default. To access the switch via the BBI, open a Web browser win- dow and type in the URL using the IP interface address of the switch. For example:
http://192.168.70.127
Access via HTTPS
BBI access via HTTPS is disabled by default. Use the following CLI command to enable HTTPS access:
>>/cfg/sys/access/https/access ena
Before you can access the BBI via HTTPS, you must generate a certificate to be used during the key exchange. Use the CLI command below to generate the HTTPS certificate. A default certificate is created the first time you enable HTTPS, but you can create a new certificate defining the information you want to be used in the various fields.
>>/cfg/sys/access/https/generate
Country Name (2 letter code) [ ]: <country code>
State or Province Name (full name) []: <state>
Locality Name (eg, city) []: <city>
Organization Name (eg, company) []: <company>
Organizational Unit Name (eg, section) []: <organizational unit>
Common Name (eg, YOUR name) []: <name>
Email (eg, email address) []: <email address>
Confirm generating certificate? [y/n]: y
Generating certificate. Please wait (approx 30 seconds) restarting SSL agent
68 Chapter 6: Configuring Switch Access | BMD00082, February 2009 |