SmartConnect User’s Guide
ServerMobility General Configuration
Use this window to configure global settings for the ServerMobility feature.
Table 9-9 ServerMobility - General Configuration Fields
Field | Description |
|
|
Server Mobility State | Enables or disables the ServerMobility feature on the |
| VSE SmartConnect software. |
|
|
Relay on | Enables or disables BOOTP Relay for all ports that have |
Mobility Ports | ServerMobility disabled. |
|
|
Server Mobility Scheme | Selects the scheme to be used for encoding the option 82 information in |
| the DHCP request packets, as follows: |
| Switch: The switch name is encoded in the agent circuit ID sub- |
| option. |
| Chassis: The chassis ID is encoded as the agent circuit ID sub- |
| option. |
| Vmac: The virtual MAC address of the server blade port is encoded |
| in the agent circuit ID |
|
|
Enables or disables DHCP failover for the ServerMobility ports. When | |
| enabled, a backup blade server will get the same IP address as the active |
| blade server if and when the active blade server goes down. |
|
|
Auto_Recovery Failover | Sets the lease time for the temporary IP address assigned by the switch |
Time | to a backup (standby) blade server while the active blade server is up. |
Set Server Mobility configu- Resets ServerMobility feature parameters to factory default values. ration to factory default
BMD00082, February 2009 | Chapter 9: Switch Policies 115 |