![](/images/backgrounds/110365/110365-12489x1.png)
Thermal Solution Quality and Reliability Requirements
11Thermal Solution Quality and Reliability Requirements
11.1Reference Heatsink Thermal Verification
Each motherboard, heatsink and attach combination may vary the mechanical loading of the component. Based on the end user environment, the user should define the appropriate reliability test criteria and carefully evaluate the completed assembly prior to use in high volume. The Intel reference thermal solution will be evaluated to the boundary conditions in Chapter 5.
The test results, for a number of samples, are reported in terms of a
+ 3σ value for thermal characterization parameter using the TTV.
11.2Mechanical Environmental Testing
Each motherboard, heatsink and attach combination may vary the mechanical loading of the component. Based on the end user environment, the user should define the appropriate reliability test criteria and carefully evaluate the completed assembly prior to use in high volume. Some general recommendations are shown in Table
The Intel reference heatsinks will be tested in an assembled to the LGA1155 socket and mechanical test package. Details of the Environmental Requirements, and associated stress tests, can be found in Table
Table
Test1 | Requirement | Pass/Fail Criteria2 |
Mechanical Shock | 3 drops each for + and - directions in each of 3 | Visual Check and |
| perpendicular axes (that is, total 18 drops) | Electrical Functional |
| Profile: 50 g, Trapezoidal waveform, 4.3 m/s [170 in/s] | Test |
| minimum velocity change |
|
|
|
|
Random Vibration | Duration: 10 min/axis, 3 axes | Visual Check and |
| Frequency Range: 5 Hz to 500 Hz | Electrical Functional |
| 5 Hz @ 0.01 g2/Hz to 20 Hz @ 0.02 g2/Hz (slope up) | Test |
|
| |
| 20 Hz to 500 Hz @ 0.02 g2/Hz (flat) |
|
| Power Spectral Density (PSD) Profile: 3.13 g RMS |
|
|
|
|
Thermal Cycling | Visual Check and | |
| minutes per cycle for 500 cycles. | Thermal Performance |
|
| Test |
|
|
|
Notes:
1.It is recommended that the above tests be performed on a sample size of at least ten assemblies from multiple lots of material.
2.Additional pass/fail criteria may be added at the discretion of the user.
Thermal/Mechanical Specifications and Design Guidelines | 89 |