Understanding the printer menus

164

 

 

 

 

Use

To

Configure Log

Specify whether and how the audit logs are created.

Enable Audit

Notes:

 

Yes

 

“Enable Audit” determines if events are recorded in the secure audit log and remote syslog. No is the

 

No

 

factory default setting.

Enable Remote Syslog

“Enable Remote Syslog” determines if logs are sent to a remote server. No is the factory default

 

Yes

 

setting.

 

No

 

“Remote Syslog Server” determines the value used to send logs to the remote syslog server. 4 is the

Remote Syslog Server

factory default setting.

 

[256 character string]

 

“Remote Syslog Port” identifies the port over which the printer transmits logged events to a remote

Remote Syslog Port

server.

 

1–65535

 

“Remote Syslog Method” identifies the protocol used by the printer to transmit logged events to a

Remote Syslog Method

remote server. Normal UDP is the factory default setting.

 

Normal UDP

 

“Remote Syslog Facility” determines the Facility value that the printer uses when sending events to

 

Stunnel

 

the remote syslog server. 4 is the factory default setting.

Remote Syslog Facility

“Log full behavior” determines how the printer resolves if the log entirely fills its allotted memory.

 

0–23

 

“Wrap over oldest entries” is the factory default setting.

Log full behavior

The value of the “Admin’s email address setting can be a single email address or a commadelimited

 

Wrap over oldest entries

 

list of email addresses.

 

Email log then delete all entries

 

“Digitally sign exports” determines if the printer automatically signs each exported security log. Off is

Admin’s e-mail address

the factory default setting.

 

[256 character string]

 

“Severity of events to log” records the severity value of each event. 4 is the factory default setting.

Digitally sign exports

“Remote Syslog non-logged events” determines if the printer sends events to the remote server that

 

Off

 

have a severity level greater than the value of the “Severity of events to log” setting. No is the factory

 

On

 

default setting.

Severity of events to log

“E-mail log cleared alert” determines if the printer sends an email to the administrator every time a

 

0–7

 

log is deleted via printer control panel or EWS. No is the factory default setting.

Remote Syslog non-logged events

“E-mail log wrapped alert” determines if the printer sends the administrator an email when log

 

No

 

entries are wrapping. No is the factory default setting.

 

Yes

 

“% full alert level” determines if the space occupied by log equals or exceeds the value of the full alert

E-mail log cleared alert

level. 90 is the factory default setting.

 

No

“E-mail % full alert” determines if the printer sends the administrator an email when the log fills a

 

Yes

 

certain amount of its allotted space. No is the factory default setting.

E-mail log wrapped alert

“E-mail log exported alert” determines if the printer sends the administrator an email when there is a

 

No

log exported. No is the factory default setting.

 

Yes

“E-mail log settings changed alert” determines if the printer sends the administrator an email when

E-mail % full alert

the value of the Enable Audit Log setting is toggled.

 

No

 

 

 

Yes

 

 

% full alert level

 

 

 

1–99

 

 

E-mail log exported alert

 

 

 

No

 

 

 

Yes

 

 

E-mail log settings changed alert

 

 

 

No

 

 

 

Yes

 

 

Log line endings

 

 

 

LF (\n)

 

 

 

CR (\r)

 

 

 

CRLF (\r\n)

 

 

 

 

 

 