A.Gas Utility Rough-In Recommendations
The following gas system specifications are STRONGLY RECOMMENDED. Deviating from these recommendations may affect the baking performance of the oven.
Gas Meter - 650 cfh meter
Gas Line
•DEDICATED LINE from the gas meter to the oven
•2" (50.8mm) pipe for natural gas
•
•Maximum length: 200' (61m). Each 90° elbow equals 7' (2.13m) of pipe.
B.Connection
Check the oven’s gas supply requirements before making the gas utility connection. Gas supply requirements are listed on the oven’s serial plate and in Table
Check the serial plate to determine the type of gas (Propane or Natural) to be used with the oven.
Refer to the instructions in the gas hose package (included in the Installation Kit) before connecting the gas line. One gas line connection method is shown in Figure
Inlet and regulated gas pressure readings can be taken using a “U” tube manometer at the tap locations shown in Figure 2- 15.
NOTE
In the USA, the installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1.
In Canada, the installation must conform with local codes, or in the absence of local codes, with the Natural Gas Installation Code,
In Australia, the installation must conform with AGA Code AG601 and with any requirements of the appropriate statutory authority.
Certain safety code requirements exist for the installation of gas ovens; refer to the beginning of Section 2 for a list of the installation standards. In addition, because the oven is equipped with casters, the gas line connection shall be made with:
•A connector that complies with the Standard for Connec- tors for Movable Gas Appliances, ANSI Z21.69 (in USA), or Connectors for Movable Gas Appliances,
•A
C.Gas Conversion
Where permitted by local and national codes, it is possible to convert ovens from natural to propane gas, or from propane to natural gas. Use the appropriate Middleby Marshall Gas Conversion Kit for the specific oven model.
CAUTION
The terms of the oven's warranty require all
Figure 2-14 - Flexible Gas Hose Installation
90°
Elbow
To Gas
Supply Pipe
Union OR | ||
quick- | ||
Gas | ||
disconnect | ||
Shutoff | ||
device | ||
Valve | ||
| ||
| Flexible | |
| Gas Hose |
Figure 2-15 - Gas Burner and Piping Assembly
Pilotburners (2) assembly
Modulating gas valve
Manifold
pressure tap
(where manifold gas pressure is measured)
Combination Gas
Control Valve
(Safety Regulator)
On/Off Switch
Always leave in “ON” position
Inlet pressure
tap (where
incoming gas
pressure is measured)