7. Setting the functions (Memory SW menu)

MARGIN CUT

 

 

Function

Cut the print paper so that the upper margin is small.

 

 

ON .......... Small margin

 

 

OFF ........ Behind the margin

 

 

 

Margin cut

 

ON

OFF

 

This function is convenient when putting the print on prints on records or non-PVC sleeves for print

 

orchiving. This feature also saves paper.

 

V POSITION

 

 

Function

Adjusting the vertical position of printing image.

 

 

Setting area - 40 to +40 ( Change each 2 lines)

 

When 2-image printing (selected “2” in “IMAGES”) on L size print paper, the printed image will not be correct depending on memory size. It may be necessary to adjust part of the image in the UP, DOWN, RIGHT or LEFT direction.

V POSITION function is to adjust the position for UP and DOWN direction of the image in memory and to print the image in the normal cutting position. This function is available only when printing 2multi-image on L size paper and selecting “2” in “IMAGES”.

ECHO GAMMA ADJ

Function Change the gamma value of “ECHO” for medical equipment.

The gamma curve is set for medical equipment in MAIN MENU 4.PRINT GRAD : ECHO . When the set gamma curve cannot be applied, this function is able to set according to connecting device. The set value is applied to the value of ECHO.

The gamma characteristic of printed image can be changed by inputting the value of a, b and c on the gamma curve.

a

(cordinates of the x1 point,

changed value y1)...... dark part of the image gets

 

 

 

 

 

 

 

 

 

 

 

 

y1

+ : brighter

 

–: darker

 

 

 

 

 

 

 

 

 

 

 

b

(cordinates of the x2 point,

changed value y2 )...... the whole image get

a ( cordinates of the x1value, changed value y1)

 

y2 + : brighter

–: darker

 

 

 

 

 

 

 

 

 

 

 

c

(cordinates of the x3 point,

changed value y3 )...bright part of the image gets

 

 

 

 

 

y3

c:(

 

x3,y3 )

 

 

 

 

y3

+ : brighter

–: darker

 

 

y2

 

 

 

 

 

 

 

 

 

 

 

 

b:( x2,y2 )

 

 

 

 

 

 

Y

 

y1

 

 

 

 

 

 

• At X, input the location of a point on the curve to be moved to Y direction.

 

 

a:( x1,y1 )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• At Y, input the amount of move.

 

 

 

 

 

 

 

 

 

 

 

 

 

darker

 

 

 

 

 

 

lighter

 

 

x1 cordinate x2cordinate x3cordinate

 

 

 

• All the gamma characteristic changes by moving the “y” on a, b or c point.

 

range

X range range

 

 

 

x: cordinates of the x1value, y: changed value y1

• The setting area of the points (a, b and c ) is limited.

Select the item to be changed by LEFT or RIGHT shift button.

a:( , ) ← → b : ( , ) ← → c : ( , ) Change the value by UP or DOWN shift button. e.g.

1b (x 2 value, y 2 changing value )..... Change the y value of all of the image.

2Change the value of a and c.

a : x1=64 y1=0 b : x2=128 y2=0 c : x3=192 y3=0 is the initial setting of “GRAD:ECHO”.

63

Page 64
Image 64
Mitsubishi Electronics CP700E operation manual Margin cut