CP3BT26

Symbol

Parameter

Conditions

Min

Max

Units

 

 

 

 

 

 

IO(Off)

Output Leakage Current

0V Vout Vcc

-2.0

2.0

µA

 

(I/O pins in input mode)

 

 

 

 

 

 

 

 

 

 

Icca1

Digital Supply Current Active Mode b

Vcc = 2.75V,

 

20

mA

 

 

IOVcc=3.63V

 

 

 

 

 

 

 

 

 

Iccprog

Digital Supply Current Active Mode c

Vcc = 2.75V,

 

20

mA

 

 

IOVcc = 3.63V

 

 

 

 

 

 

 

 

 

Iccps

Digital Supply Current Power Save Mode d

Vcc = 2.75V,

 

4

mA

 

 

IOVcc =3.63V

 

 

 

 

 

 

 

 

 

Iccid

Digital Supply Current Idle Mode e

Vcc = 2.75V,

 

2

mA

 

 

IOVcc = 3.63V

 

 

 

 

 

 

 

 

 

Iccq

Digital Supply Current Halt Mode e,f

Vcc = 2.75V,

 

150

µA

 

 

IOVcc = 3.63V,

 

 

 

 

 

20°C

 

 

 

 

 

 

 

 

 

a. Guaranteed by design

b. Run from internal memory (RAM), Iout = 0 mA, X1CKI = 12 MHz, PLL enabled (4×), internal system clock is 24 MHz, not programming Flash memory

c. Same conditions as Icca1, but programming or erasing Flash memory page

d. Running from internal memory (RAM), Iout = 0 mA, XCKI1 = 12 MHz, PLL disabled, X2CKI = 32.768 kHz, device put in power-save mode, Slow Clock derived from XCKI1

e. Iout = 0 mA, XCKI1 = Vcc, X2CKI = 32.768 kHz

f. Halt current approximately doubles for every 20°C.

www.national.com

244

Page 244
Image 244
National CP3BT26 manual IOOff