Switch Settings (Continued)
|
| SWITCH | SWITCH | SETTING |
|
| FUNCTION |
|
|
|
| CHECK | |||
|
| NAME | NUMBER | POSITION |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| 1 | ON | • Common channel signalling data transmission speed |
| ||||||||
|
|
|
|
| (For Digital Interface) |
|
|
|
|
|
|
| |||
|
|
|
| OFF |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TRANSMISSION | SW | SW |
| SW | SW | SW |
|
|
|
|
|
|
| ON |
| |||||||||
|
|
|
| 2 |
| SPEED |
|
|
| ||||||
|
|
|
|
|
|
|
|
| |||||||
|
|
|
| OFF |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 48Kbps ¨ | ON | ON |
| OFF | OFF | ON |
|
| |
|
|
|
|
|
|
| 48Kbps ¦ | ON | ON |
| ON | OFF | ON |
|
|
|
|
|
|
| ON |
| |||||||||
|
|
|
| 3 |
| 56Kbps | ON | ON |
| OFF | ON | ON |
|
| |
| SW1(Dip SW) |
|
| 64Kbps | ON | ON |
| ON | ON | ON |
|
| |||
| OFF |
|
|
|
| ||||||||||
|
|
|
|
|
| ||||||||||
|
| • Common channel signalling data transmission speed |
| ||||||||||||
|
|
|
|
|
|
| |||||||||
|
|
|
|
| ON |
| |||||||||
ON |
|
| 4 | (For Analog Interface) |
|
|
|
|
|
|
| ||||
1 2 3 4 5 6 7 8 |
|
|
|
|
|
|
|
|
| ||||||
|
| Set switches |
|
|
| ||||||||||
OFF |
|
|
| ||||||||||||
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5 | ON |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| OFF |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 6 | ON |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| OFF |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 7 | OFF | Always set to OFF |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 8 | OFF | Always set to OFF |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The figure in the SWITCH NAME column and the position in in the SETTING POSITION col- umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned.
Note 1: Set the groove on the switch knob to the desired switch position.
Note 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card.
Note 3: This setting is available when
Note 4: The followimg two kinds of rate adaptation method are available when using 48 Kbps data transmis- sion. The rate adaptation method must be set to match the rate adaptation of the master office.
1 SW1-3: OFF
48 Kbps
1
Data
1
2 SW1-3: ON
48 Kbps
1
Data
1
CHAPTER 4 |
Page 90
Revision 2.0