NEC 2000 IVS manual •More than one PIM is used •A PN-2DLCCis used

Models: 2000 IVS

1 156
Download 156 pages 58.89 Kb
Page 19
Image 19
•More than one PIM is used.

2.INSTALLATION CONDITIONS FOR CONTROL CIRCUIT CARDS

2.1 PN-CP00/PN-CP00-B/PN-CP00-C (MP)

Mount the PN-CP00/PN-CP00-B/PN-CP00-C in the MP slot of PIM0.

2.2 PN-CP01 (FP)

1.The PN-CP01 is required only if any of the following is true.

More than one PIM is used.

A PN-2DLCC is used.

A PN-AP01 is used.

OAI, ACD, No. 7 CCIS or ISDN is used.

2.When the system is equipped with two PIMs, mount one PN-CP01 in the FP slot of PIM0. When the sys- tem is equipped with more than two PIMs--depending on the number of additional PIMs used--mount one PN-CP01 in the FP slot of PIM0 and one PN-CP01 in the MP/FP slot of PIM2, PIM4 and PIM6.

PIM3

PIM7

PIM2

F P

F P

PIM6

PIM1

PIM5

PIM0

F P

M P

F P

PIM4

Figure 3-2 MP/FP Card Mounting Slots

ND-45504 (E)

CHAPTER 3

Addendum-002

Page 11

OCTOBER, 1998

Revision 2.2