PN-24DTA-A (DTI)
1.Location of Lamps, Switches, and Connectors
[When Card Issue No. is before 5A]
AISS
MAS
JPR1 JPS
JPR0
SENS
RUN
MB
SW
CRC PCM FRM RMT AIS BL
[When Card Issue No. is after 5B]
AISS
MAS
JPR1 JPS
JPR0
SENS
RUN
MB
SW
CRC PCM FRM AIS RMT BL
2.Lamp Indications
|
|
| Lamp Indications | |
|
|
|
| |
LAMP NAME | COLOR |
| FUNCTION | |
|
|
| ||
RUN | Green | Flashes at 120 IPM while this card is operating normally. | ||
|
|
| ||
CRC | Red | Lights when detecting Cyclic Redundancy Checking (CRC) errors. | ||
|
|
| ||
PCM | Red | Lights when detecting PCM signal loss. | ||
|
|
| ||
FRM | Red | Lights when detecting a Frame Alignment signal loss. | ||
|
|
| ||
RMT | Red | Lights when receiving a Frame Alignment signal loss alarm from a distant office. | ||
|
|
| ||
AIS | Red | Lights when a pattern of consecutive “1” is received. The distant office transmits this signal | ||
for a | ||||
|
| |||
|
|
| ||
|
| B channel status | ||
|
| ON | : More than 10 channels is busy | |
BL | Red | OFF | : All channels are idle | |
|
| Flash (60 IPM):Only one channel is busy | ||
|
| Flash (120 IPM):2 through 10 channels are busy | ||
|
|
|
|
Page 75