NEC 2000 IVS manual Switch Settings, Always set to OFF

Models: 2000 IVS

1 156
Download 156 pages 58.89 Kb
Page 145
Image 145
Manual background

PN-2ILCA (ILC)

(3) Switch Settings

Switch Settings

 

SWITCH

SWITCH

SETTING

 

FUNCTION

CHECK

 

NAME

NUMBER

POSITION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW1

1

OFF

Always set to OFF

 

(Piano Key SW)

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

OFF

Always set to OFF

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

3

OFF

Always set to OFF

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

OFF

Always set to OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW0

1

ON

No. 0 Circuit

Terminating register is provided.

 

(Piano Key SW)

 

(Receiving)

 

 

OFF

Terminating register is not provided.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

2

ON

No. 0 Circuit

Terminating register is provided.

 

 

 

 

 

 

 

 

 

 

(Sending)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

Terminating register is not provided.

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

3

ON

No. 1 Circuit

Terminating register is provided.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

(Receiving)

 

 

 

 

 

 

 

 

 

 

OFF

Terminating register is not provided.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

4

ON

No. 1 Circuit

Terminating register is provided.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Sending)

 

 

 

 

 

 

 

 

 

 

 

 

OFF

Terminating register is not provided.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The figure in the SWITCH NAME column and the position in Manual background in the SETTING POSITION col- umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and Manual background , the setting of the switch varies with the system concerned.