PN-CK00 (PLO)
Note 1: When the power is on, flip the MB switch ON (UP position) before plugging/unplugging the circuit card.
Note 2: When using this card, set the SW2 switch on the PN-CP00/PN-CP00-B/PN-CP03 (MP) as follows.
SW2-2: OFF
SW2-3: ON
Note 3: When using this card for providing a master office clock signal, set the SW0 switch on the PN-CK00 and the SW switch on the PN-24DTA/PN-24DTA-A or the PN-30DTC/PN-30DTC-A mounted in PIM0 as fol- lows.
• PN-CK00 card | • PN-24DTA/PN-24DTA-A card | • PN-30DTC/PN-30DTC-A card |
SW0-1: OFF | SW-1: OFF | SW-1: OFF |
SW0-2: OFF | SW-2: OFF | SW-2: OFF |
SW0-3: OFF | | |
SW0-4: OFF | | |
SW0-8: ON | | |
Note 4: When using this card as a sub-master, set the SW0 switch on the PN-CK00 and the SW switch on the PN-24DTA/PN-24DTA-A or the PN-30DTC/PN-30DTC-A as follows:
For 1.5MHz interface: | |
• PN-CK00 card | • PN-24DTA/PN-24DTA-A card |
SW0-1: OFF | SW-1: ON |
SW0-2: ON | SW-2: OFF |
SW0-3: OFF | |
SW0-4: ON* | |
SW0-8: ON | |
*Set to ON, when more than one DTI card is mounted in PIM0, or set to OFF when only one DTI card is mounted in PIM0.
For 2MHz interface: | |
• PN-CK00 card | • PN-30DTC/PN-30DTC-A card |
SW0-1: ON | SW-1: ON |
SW0-2: ON | SW-2: OFF |
SW0-3: ON | |
SW0-4: ON* | |
SW0-8: ON | |
*Set to ON, when more than one DTI card is mounted in PIM0, or set to OFF when only one DTI card is mounted in PIM0.
ND-45504 (E) | CHAPTER 4 |
Addendum-001 | Page 71 |
JULY, 1998 | Revision 2.1 |