NEC 2000 IVS manual For 1.5MHz interface, For 2MHz interface

Models: 2000 IVS

1 156
Download 156 pages 58.89 Kb
Page 87
Image 87

PN-CK00 (PLO)

Note 1: When the power is on, flip the MB switch ON (UP position) before plugging/unplugging the circuit card.

Note 2: When using this card, set the SW2 switch on the PN-CP00/PN-CP00-B/PN-CP03 (MP) as follows.

SW2-2: OFF

SW2-3: ON

Note 3: When using this card for providing a master office clock signal, set the SW0 switch on the PN-CK00 and the SW switch on the PN-24DTA/PN-24DTA-A or the PN-30DTC/PN-30DTC-A mounted in PIM0 as fol- lows.

PN-CK00 card

PN-24DTA/PN-24DTA-A card

PN-30DTC/PN-30DTC-A card

SW0-1: OFF

SW-1: OFF

SW-1: OFF

SW0-2: OFF

SW-2: OFF

SW-2: OFF

SW0-3: OFF

 

 

SW0-4: OFF

 

 

SW0-8: ON

 

 

Note 4: When using this card as a sub-master, set the SW0 switch on the PN-CK00 and the SW switch on the PN-24DTA/PN-24DTA-A or the PN-30DTC/PN-30DTC-A as follows:

For 1.5MHz interface:

 

PN-CK00 card

PN-24DTA/PN-24DTA-A card

SW0-1: OFF

SW-1: ON

SW0-2: ON

SW-2: OFF

SW0-3: OFF

 

SW0-4: ON*

 

SW0-8: ON

 

*Set to ON, when more than one DTI card is mounted in PIM0, or set to OFF when only one DTI card is mounted in PIM0.

For 2MHz interface:

 

PN-CK00 card

PN-30DTC/PN-30DTC-A card

SW0-1: ON

SW-1: ON

SW0-2: ON

SW-2: OFF

SW0-3: ON

 

SW0-4: ON*

 

SW0-8: ON

 

*Set to ON, when more than one DTI card is mounted in PIM0, or set to OFF when only one DTI card is mounted in PIM0.

ND-45504 (E)

CHAPTER 4

Addendum-001

Page 71

JULY, 1998

Revision 2.1

Page 87
Image 87
NEC 2000 IVS manual For 1.5MHz interface, For 2MHz interface