8-8 User’s Reference Guide

Frame Relay configuration

If you chose Frame Relay as your data link encapsulation type you can now configure the Frame Relay options from the WAN Configuration menu.

WAN Configuration

WAN (Wide Area Network) Setup...

Display/Change Connection Profile...

Add Connection Profile...

Delete Connection Profile...

Default Profile...

Frame Relay Configuration...

Frame Relay DLCI Configuration...

Return/Enter for WAN line configuration.

From here you will configure yours and the remote sites' WAN information.

From the WAN Configuration screen, select WAN Setup, then select the Frame Relay Configuration option and press Return. The Frame Relay Configuration screen appears.

 

Frame Relay Configuration

LMI Type...

ANSI (Annex D)

T391

(Polling Interval in secs):

10

N391

(Polls/Full Status Cycles):

6

N392

(Error Threshold):

3

N393

(Monitored Event Window):

4

Tx Injection Management...

Standard

Default CIR:

64000

Default Bc:

64000

Default Be:

0

Congestion Management Enabled:

No

Maximum Tx Frame Size:

1520

Return/Enter goes to new screen.

Enter Information supplied to you by your telephone company.

1.Select LMI Type (Link Management Type) and press Return. From the pop-up menu, highlight either ANSI (Annex D), CCITT (Annex A), LMI, or None. The default is None. Press Return.

Page 70
Image 70
Netopia R5200, R5300, R5100 manual Frame Relay configuration