Chapter 2 CLI Command Summary 129
Default
If a warning level is not given, then only alert and warning problems are shown, equivalent to:
show health warnings
Command mode
Privileged Exec
Response
See the example for output from this command.
Next command mode
Privileged Exec
Related commands
audible alarm
Example
CES#show health warnings
Alert: | LAN on slot | 2 Interface 1. Device fei1 down | |
Alert: | Auto backup | servers. Can't backup to 12.33.44.123 | |
Alert: | Voltage 2.5 | VA. | Voltage out of range |
Alert: | Chassis Fan. |
| Fan not functioning |
Warning: | Hard Disk 1. |
| Device /ide1/ not available |
Warning: | SNMP Servers. | Server not configured |
This example shows the type of output that is displayed when alerts and warning messages are requested by the show health command.
Reference for the Contivity VPN Switch Command Line Interface