98 / Troubleshooting
Example | Meaning | Possible causes and |
display |
| actions |
|
|
|
UTAM key | System disabled | Common message for a |
reqÕd |
| new installation, see |
|
| “Software keys (U.S. only)” |
|
| on page 68. The only other |
|
| time this alarm should |
|
| appear is if you are |
|
| rebuilding a system: |
|
| 1.Enter a UTAM Activation |
|
| Key. See “Software keys |
|
| (U.S. only)” on page 68. |
|
| 2.Obtain a Regression Key. |
|
| See “Obtaining a |
|
| Regression Key (U.S. |
|
| only)” on page 94. |
UTAM test | System is disabled. This |
failed | alarm appears only after |
| a restart |
-Ensure there is power to the Base Stations and RPI or
-Ensure that the location and number of Base Stations is correct
-Ensure that there are at least four cells in the system configuration
-Ensure that there are sufficient Radio Credits to support the number of Base Stations you have connected
-Restart the system with the correct system configuration.
P0881594 Issue 01 |