Nortel Networks MICS-XC manual Mounting the RPI unit, RPI Requirements

Models: MICS-XC

1 138
Download 138 pages 24.91 Kb
Page 28
Image 28

22 / Installation

RPI Requirements

Base Stations

 

RPI-16 and RPI-8 required

PSUs required

 

 

 

1–8

1 RPI-8

1 PSU

 

 

 

9–16

1 RPI-16

2 PSUs

 

 

 

 

17–24

1

RPI-16 and 1 RPI-8

3 PSUs

 

 

 

 

25–32

2

RPI-16

4 PSUs

 

 

 

 

Mounting the RPI unit

1.Position the screw holes for the RPI using the dimensions shown in the following figure.

RPI mounting holes

25 mm

325 mm

(1 in.)

(13 in.)

 

50 mm

 

(2 in.)

 

Keyholes

 

300 mm

 

(12 in.)

To provide adequate ventilation and to prevent overheating, leave a clearance of at least 125 mm (5 in.) around the RPI.

If you are mounting two RPIs, one above the other, leave a clearance of at least 300 mm (12 in.) between them to provide adequate ventilation and to prevent overheating.

MICS-XC Norstar-Companion Installer Guide

P0881594 Issue 01

Page 28
Image 28