Nortel Networks MICS-XC manual RPI Connector Overview, Wire size Single-pair Double-pair

Models: MICS-XC

1 138
Download 138 pages 24.91 Kb
Page 31
Image 31

Installation / 25

Maximum power cabling distance (approximate)

Depending on the size of cable you are using, you should remember the maximum cabling distances allowed between the RPI and the Base Station.

Wire size

Single-pair

Double-pair

 

 

 

0.6 mm (22 AWG)

450 m (1,500 ft.)

900 m (3,000 ft.)

 

 

 

0.5 mm (24 AWG)

300 m (1,000 ft.)

600 m (2,000 ft.)

 

 

 

When using two power pairs, ensure they are connected with the same polarity.

RPI Connector Overview

The following illustration shows where the input and output connectors are located on the RPI connector board.

RPI connector board

OBIX1 OBIX2 OBIX3 OBIX4

OBIX9

OBIX10 OBIX11 OBIX12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OBIX5 OBIX6 OBIX7 OBIX8

OBIX13

OBIX14 OBIX15 OBIX16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IBIX4 IBIX2 IBIX3 IBIX1

P0881594 Issue 01

MICS-XC Norstar-Companion Installer Guide