Installation / 25
Maximum power cabling distance (approximate)
Depending on the size of cable you are using, you should remember the maximum cabling distances allowed between the RPI and the Base Station.
Wire size |
|
|
|
|
|
0.6 mm (22 AWG) | 450 m (1,500 ft.) | 900 m (3,000 ft.) |
|
|
|
0.5 mm (24 AWG) | 300 m (1,000 ft.) | 600 m (2,000 ft.) |
|
|
|
When using two power pairs, ensure they are connected with the same polarity.
RPI Connector Overview
The following illustration shows where the input and output connectors are located on the RPI connector board.
RPI connector board
OBIX1 OBIX2 OBIX3 OBIX4 | OBIX9 | OBIX10 OBIX11 OBIX12 | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
OBIX5 OBIX6 OBIX7 OBIX8 | OBIX13 | OBIX14 OBIX15 OBIX16 | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
IBIX4 IBIX2 IBIX3 IBIX1
P0881594 Issue 01 |