Nortel Networks MICS-XC manual 90 / Troubleshooting

Models: MICS-XC

1 138
Download 138 pages 24.91 Kb
Page 96
Image 96

90 / Troubleshooting

The ICS or Station Module is not ON.

The Base Station is not connected to the ICS or Station Module.

The wiring to the Base Station is not correct.

The TCM wiring length between the Base Station and the ICS (or Station Module) exceeds 1200 m.

There is a faulty ICS, Station Module, or RPI.

The two-way DC loop resistance of the power pairs between the Remote Power Interconnect (RPI) and the Base Station exceeds 90 ohms. Measure the loop resistance with an ohmmeter. If the resistance exceeds 90 ohms, install a second power pair, or power the Base Station with a plug-top power supply.

The Base Station is faulty.

4.Verify that the power cord of the RPI is properly connected to a working AC outlet. If the Base Station is powered locally, verify that the power supply is properly connected to a working AC outlet and that the power supply cable is properly connected to the Base Station power connector

5.If an external antenna is installed, verify that the external antenna coaxial cable is properly connected to the BNC connector of the Base Station and that the corresponding radio is programmed to have an external antenna (see “Installing external antennas and lightning surge arrestors” on page 37).

Note: Ensure there are not any bridge taps on the TCM.

MICS-XC Norstar-Companion Installer Guide

P0881594 Issue 01

Page 96
Image 96
Nortel Networks MICS-XC manual 90 / Troubleshooting