Configuring a new ELAN ID and VAS ID (LD 17)

Define and configure the ELAN subnet for the AML link and its associated VAS ID in the configuration record. This provides the Ethernet connection over which AML messages are exchanged between the CS 1000 or M1 system and CallPilot. A separate ELAN must be created for CallPilot and Contact Center for the purpose of integration.

Perform this procedure only if there is no VAS ID provisioned or available.

Step Action

1Connect to the PBX.

2Enter LD 17.

3Enter the appropriate values as described in the following table to configure a new ELAN ID. For prompts not listed in the following table, press Enter to accept the default.

Table 2

LD 17 - Configuring the ELAN ID

Prompt

Response

Notes

 

 

 

REQ

CHG

 

 

 

 

TYPE

ADAN

 

 

 

 

ADAN

NEW ELAN xx

Where xx is the next available

 

 

number, 16 – 31.

 

 

 

CTYP

ELAN

 

 

 

 

DES

a..a

Enter a relevant description (for

 

 

example, CallPilot).

 

 

 

LCTL

<cr>

 

 

 

 

4Enter the appropriate values as described in the following table to configure a new VAS ID. For prompts not listed in the following table, press Enter to accept the default.

Table 3

LD 17 - Configuring the VAS ID

Prompt

Response

Notes

 

 

 

REQ

CHG

 

 

 

 

TYPE

VAS

 

 

 

 

VAS

NEW

 

 

 

 

VSID

xx

Enter the number entered for

 

 

the ELAN ID above.

 

 

 

Nortel CallPilot

Quickstart Guide

NN44200-313 01.02 Standard

5.019 May 2008