44CallPilot server installation

3Install the power cords to all devices, but plug them only into the receptacle, not into the end device. The devices requiring power are:

1005r server — two power cords, redundant power supplies

600r server — one power cord

monitor — one power cord

tape drive — one power cord

ELAN subnet Ethernet switch or hub — one power cord

Nortel server subnet Ethernet switch or hub — one power cord

Note: The single-point ground (SPG) required by the system can be an isolated ground (IG) bus or AC equipment ground (ACEG) bus in the service panel or transformer. The system must be connected to a safety ground or protective earth in accordance with NEC requirements. For international use, the system must be connected to safety ground or protective earth in accordance with Paragraph 2.5 of EN60950/IEC950.

4Check the version of your MPB96 card or cards before proceeding. The versions are identified as follows:

The NTRH40CA MPB96 board has three RJ-45 connectors on its faceplate. If you have an NTRH40CA, proceed to step 5.

The NTRH40AA MPB96 board has a single DB-44 connector on its faceplate. The MPB96 connects to the MGate using a DS30X cable. If you have an NTRH40AA, proceed to step 6.

5Install and connect the DS30 cables from the switch MGATE card to the CallPilot MPB96. There is no restriction as to which cable is connected first, as the NTRH40AC MPB96 can get its timing from any of the three RJ-45 ports.

The RJ-45 connectors in the top MPB96 card are numbered from 1 to 3 starting at the right side of the server’s back panel (next to the power supplies) They are cabled to MGate cards 1 to 3 respectively

If there are three MPB96 cards in your server, the RJ-45 connectors in the middle card are cabled (from right to left) to MGate cards 4 to 6. The bottom MPB96 card is not connected to the switch.

Continue with "Performing preboot checks" (page 45)