Configure Branch

Table 9-8

(4 of 4)

Miscellaneous Configuration Options

*NetworkPosition: Tributary

Nxt Tributary Control

Network Position Identification. Each modem must be identified either as a control modem or a tributary modem.

NOTE: This configuration option is only applicable for leased-line network management applications.

For the Model 3810 and Model 3820, Tributary is the factory default.

For the Model 3811, Control is the factory default.

AT command for Tributary is S74 = 0.

AT command for Control is S74 = 1.

CellulrRJ11Adpt: Disable

End Disable Enable

Cellular RJ11 Adapt. Allows the modem to support an RJ11 connection to a 3-watt phone. It also causes the modem to transmit the ETC 1.1 Calling Tone during call origination.

Disable ± No RJ11 support or ETC 1.1 Calling Tone.

Enable ± For use when the Cellular(Mobile) factory template is loaded, enable RJ11 support and ETC 1.1 Calling Tone.

AT Command to Disable is S-register S93 = 0.

AT Command to Enable is S-register S93 = 1.

* This configuration option only appears if the 6700 Series NMS option is installed.