Status Branch

Options

The Options Status function displays all optional firmware features currently installed in the modem (for example, V.29, V.33, and dial network management). If no firmware options are installed, None_Installed appears on the LCD.

To access Options from the Status branch, make the following sections:

Status:

 

 

RS366A

 

Options

F1

F2

F3

Press the key until Options appears. Select Options.

Options' Status

>

V.29

 

V.33

F1

F2

F3

If optional features are installed in the modem, they appear on the LCD's bottom line. If other features are

installed, press the key to scroll other features into view.

Record

Record is a troubleshooting tool used by the end user in conjunction with support personnel. This function allows the end user to retrieve and report any sequence faults to support personnel. A sequence fault is an irregular or unexpected event.

There are two selections under Record: Display and

Clear. Display allows up to eight sequence fault messages that have been recorded by the modem to be displayed on the LCD. If no sequence faults have occurred, then Modem O.K. appears.

Clear is used to remove all sequence fault messages from nonvolatile memory and the LCD.

To access Record from the Status branch, make the following selections:

Status<

Options Record

F1 F2 F3

Press the key until Record appears. Select Record.

Record Status

Display Clear

F1 F2 F3

To display sequence faults, select Display.

Record Number 1

Modem O.K.

F1 F2 F3

The LCD displays the first sequence fault field. (Sequence fault fields range from 1 to 8 and are identified

by a number in the upper right corner.) Press the key to view the remaining fields. The message Modem O.K. appears if no sequence faults have occurred.

To remove sequence fault records from both the LCD and nonvolatile memory, select Clear. The message Modem O.K. appears.

To exit this function and remain in the Status branch,

press the key. To exit and return to the Top-Level

menu, press the key.

AT Command Equivalent

There is no AT command for Record.

3810-A2-GB30-20

November 1996

7-5

Page 55
Image 55
Paradyne 3810 manual Options, Record