Line Dialer Configuration Options

MI/MIC Dialing: Disable

End Disable Enable

MI/MIC Dialing. Also known as D-Lead signaling, is required by some PBX systems, older data phones, and security callback systems. It forces the modem into the originate handshake after first dialing a call.

Disable ± Modem ignores activity on the MI/MIC contacts.

Enable ± When Pins 3 and 6 of the TELCO jack (Models 3810 and 3820) are connected then disconnected, the modem goes off-hook and looks for the answer sequence from the remote modem. If the sequence is detected, the local modem will handshake and connect with the remote modem. A 26-pin D-Lead control connector is located on the rear of the 3000 Series Carrier. This connector is used for MI/MIC Dialing for Model 3811 modems.

The factory default is Disable.

AT command is S-register S83 = n, where n is 0 for Disable and 1 for Enable.