AT Command Set and S-Registers

S-Register

Table 14-2

(2 of 11)

3800 Series S-Registers

Description

Front Panel Branch

 

 

S8

``,º Pause Time for the Dial Modifier

Configure\Edit\Line Dialer

 

Register determines how long (in seconds) the modem pauses when it

 

 

encounters a comma (,) in the Dial command string.

 

 

Enter a value from 0 to 255 seconds.

 

 

Factory setting is 2 seconds.

 

 

 

 

S10

No Carrier Disconnect

Configure\Edit\Line Dialer

 

Register determines how long (in tenths of seconds) the modem allows

 

 

the carrier signal to be off before disconnecting the call.

 

 

Enter a value from 0 to 254 in 0.1 second increments. (A value of 255

 

 

disables this register.)

 

 

Factory setting is 20 (2 seconds).

 

 

 

 

S12

Escape Guard Time

Configure\Edit\DTE Dialer

 

Register sets the value (in 20-millisecond increments) for the required

 

 

pause before and after the escape sequence is issued. The guard time

 

 

prevents the modem from interpreting data as the escape sequence

 

 

characters.

 

 

Enter a value from 0 to 255 in 20-millisecond increments. For example,

 

 

the factory setting of 50 equals 1000 milliseconds or one second.

 

 

Factory setting is 50 (1 second).

 

 

 

 

S18

Test Timeout

Configure\Edit\Tests

 

Register sets the duration (in seconds) for the modem tests. This

 

 

automatically cancels any test in progress after the time of this register

 

 

expires. Any test can be manually canceled by issuing the escape

 

 

sequence (+++) followed by the &T0 command.

 

 

Enter a value from 0 to 255 seconds. (A value of 0 disables this register.)

 

 

Factory setting is Disable (0).

 

 

 

 

S26

RTS-to-CTS Delay

Configure\Edit\DTE

 

Register sets the length of time (in 10-millisecond increments) the

Interface

 

modem waits after receiving RTS before issuing CTS to the DTE.

 

 

Enter a value from 0 to 255.

 

 

Factory setting is 0 milliseconds.

 

 

 

 

S34

1800 Hz Training Tone

Configure\Edit\Leased Line

 

This configuration option is for communication with certain modems that

 

 

do not comply with the V.32 standard. When 1800 Hz Training Tone is

 

 

enabled, a short burst of 1800 Hz (AC) tone is sent to the answering

 

 

modem to prompt it to answer. This is not required for V.32-compliant

 

 

modems.

 

 

Register has the following values:

 

 

0 = Disable

 

 

1 = Enable

 

 

Factory setting is Disable.

 

 

 

 

3810-A2-GB30-20

November 1996

14-17

Page 151
Image 151
Paradyne 3810 manual Register Series S-Registers Description Front Panel Branch