COMSPHERE 3800 Series Modems

S-Register

Table 14-2

(5 of 11)

3800 Series S-Registers

Description

Front Panel Branch

 

 

S43

V.32bis Train

Configure\Edit\Dial Line

 

Register controls the modem's train time for V.32bis/V.32 mode.

 

 

Register has the following values:

 

 

0 = Long

 

 

1 = Short

 

 

Factory setting is Long.

 

 

 

 

S44

Leased-Line Rate

Configure\Edit\Leased Line

 

Register determines the modem's data rate and modulation scheme for

 

 

operation on either 2-wire or 4-wire leased lines in either Answer or

 

 

Originate mode.

 

 

Register has the following values:

 

0, 1 = 14,400 (V.32bis)

2= 12,000 (V.32bis)

3= 9600 (V.32bis)

4= 7200 (V.32bis)

5= 4800 (V.32bis)

6= 2400 (V.22bis)

18= 19,200 (V.32terbo)

19= 16,800 (V.32terbo)

Factory setting is 19,200 (V.32terbo).

S45

Leased TX Level

Configure\Edit\Leased Line

 

Register determines the modem's transmit power output level over

 

 

leased lines.

 

 

Enter a value from 0 to 15 dBm.

 

 

Factory setting is 0 dBm.

 

 

 

 

S46

Bad Lines Auto Originate

Configure\Edit\Leased Line

 

Register determines if the modem performs an automatic dial backup if

 

 

the leased lines fail.

 

 

Register has the following values:

 

 

0 = Disable

 

 

1

= 30 seconds

 

 

2

= 20 seconds

 

 

3

= 60 seconds

 

 

4

= 90 seconds

 

 

5

= 120 seconds

 

 

S

S

 

 

S

S

 

 

21 = 600 seconds

 

 

Factory setting is Disable. Note that the S46 = 2 command has an effect

 

 

that is out of sequence with the other values.

 

 

 

 

 

14-20

November 1996

3810-A2-GB30-20

Page 154
Image 154
Paradyne 3810 manual 32bis Train, Leased-Line Rate, Leased TX Level, Bad Lines Auto Originate