Paradyne 3810 25bis Coding, 25bis Idle Character, 25bis New Line Character, NMS Call Messages

Models: 3810

1 204
Download 204 pages 3.31 Kb
Page 157
Image 157

AT Command Set and S-Registers

S-Register

Table 14-2

(8 of 11)

3800 Series S-Registers

Description

Front Panel Branch

 

 

S62

V.25bis Coding

Configure\Edit\DTE Dialer

 

Register identifies to the modem the type of coding used by the DTE

 

 

while in V.25bis mode.

 

 

Register has the following values:

 

 

0

= ASCII

 

 

1

= EBCDIC

 

 

Factory setting is ASCII.

 

 

 

 

S63

V.25bis Idle Character

Configure\Edit\DTE Dialer

 

Register identifies to the modem the type of idle fill used by the DTE

 

 

while in V.25bis mode.

 

 

Register has the following values:

 

 

0

= Mark

 

 

1

= Flag

 

 

Factory setting is Mark.

 

 

 

 

S64

V.25bis New Line Character

Configure\Edit\DTE Dialer

 

Register identifies to the modem the type of line terminator used by the

 

 

DTE while in V.25bis mode.

 

 

Register has the following values:

 

 

0

= Carriage Return and Line Feed

 

 

1

= Carriage Return

 

 

2

= Line Feed

 

 

Factory setting is carriage return and line feed (CR + LF).

 

 

 

 

S65

Line Current Disconnect

Configure\Edit\Line Dialer

 

Register determines if the modem disconnects if an 8-millisecond or

 

 

90-millisecond interruption in loop current occurs.

 

 

Register has the following values:

 

 

0

= Enable (8msec)

 

 

1

= Enable (90msec)

 

 

2

= Disable

 

Factory setting is Enable (8msec).

S66

NMS Call Messages

Configure\Edit\Misc

 

Register determines if the modem sends information regarding status

 

 

(Call Progress) and/or sends summarized call statistics (Call Connect) to

 

 

the network management system (COMSPHERE 6700 Series NMS).

 

 

Register has the following values:

 

 

0

= Call Connect & Progress

 

 

1

= Disable

 

 

2

= Call Connect Only

 

 

3

= Call Progress Only

 

 

Factory setting is Call Connect & Progress.

 

 

 

 

S67

Directory Location 1 Callback

Configure\Edit\Misc

 

Register determines if the modem uses the single number callback

 

 

function.

 

 

Register has the following values:

 

 

0

= Disable

 

 

1

= Enable

 

 

Factory setting is Disable.

 

 

 

 

 