Default Configuration Options

Table G-1

(3 of 4)

Factory Default Configuration Options

Configuration Option

Async Dial and UNIX Dial Default Settings

Sync Dial

Default Settings

Sync Leased

Answer/Originate Mode

Default Settings

DIAL LINE

 

 

 

Dial Line Rate

19200(V32t)

19200(V32t)

19200(V32t)

V.32bis Automode

Enable

Enable

N/A

V.32bis Autorate

Enable

Enable

Enable

Dial Transmit Level

Permissive

Permissive

Permissive

 

±9 dBm

±9 dBm

±9 dBm

V.22bis Guard Tone

Disable

Disable

Disable

V.32bis Train

Long

Long

Long

 

 

 

 

LEASED LINE

 

 

 

Leased Mode

N/A

N/A

4-wire LL Answer**

 

 

 

4-wire LL Orig***

Leased Line Rate

N/A

N/A

19200(V32t)

V.32bis Autorate

N/A

N/A

Enable

Leased Transmit Level

N/A

N/A

0 dBm

1800 Hz Train Tone

N/A

N/A

Disable

BdLn Auto Orig

N/A

N/A

Disable

Auto Dial Standby

N/A

N/A

Disable

Carrier On Level

N/A

N/A

±43 dBm

Fall Fwd Delay

N/A

N/A

Disable

 

 

 

 

V.42/MNP/BUFFER

 

 

 

Error Control Mode

V.42/MNP or Buffer

N/A

N/A

V.42bis Compression

Enable

N/A

N/A

MNP5 Compression

Enable

N/A

N/A

EC Negotiate Buffer

Disable

N/A

N/A

EC Fallback Character

N/A

N/A

N/A

Flow Control of DTE

CTS to DTE

N/A

N/A

Flow Control of Modem

Disable

N/A

N/A

XON/XOFF Passthrough

N/A

N/A

N/A

Modem-to-Modem Flow

Disable

N/A

N/A

Control

 

 

 

Break Buffer Control

Keep Data

N/A

N/A

Send Break Control

Data First

N/A

N/A

Buffer Disconnect Delay

10 seconds

N/A

N/A

 

 

 

 

** Sync Leased Answer Mode default setting. (For the Model 3820, the default setting is 2-wire Answer.)

***Sync Leased Originate Mode default setting. (For the Model 3820, the default setting is 2-wire Originate.)

3810-A2-GB30-20

November 1996

G-3

Page 187
Image 187
Paradyne 3810 manual Dial Line