AT Command Set and S-Registers

S-Register

Table 14-2

(10 of 11)

3800 Series S-Registers

Description

Front Panel Branch

 

 

S80

No Data Disconnect Trigger Signal

Configure\Edit\Line Dialer

 

Register determines whether Pin 2 (transmit data) or Pin 3 (receive data)

 

 

of the modem's RS-232 serial interface is monitored so that the modem

 

 

can disconnect the call if there is no activity for a certain period. (See the

 

 

\T command.)

 

 

Register has the following values:

 

 

0

= Transmit or Receive

 

 

1

= Transmit only

 

 

2

= Receive only

 

 

3

= Transmit and Receive

 

 

Factory setting is 3.

 

 

 

 

S82

V.32bis Autorate (Leased Line)

Configure\Edit\Leased Line

 

Register determines if Autorating is used on leased lines when

 

 

connected in V.32bis mode.

 

 

Register has the following values:

 

 

0

= Enable

 

 

1

= Disable

 

 

Factory setting is Enable.

 

 

 

 

S83

MI/MIC Dialing

Configure\Edit\Line Dialer

 

Register determines if MI/MIC control leads can be used to force the

 

 

modem into the originate handshake after first dialing a call.

 

 

Register has the following values:

 

 

0

= Disable

 

 

1

= Enable

 

 

Factory setting is Disable.

 

 

 

 

S84

AT Command Mode

Configure\Edit\DTE Dialer

 

Register determines how the modem responds to valid and invalid AT

 

 

commands.

 

 

Register has the following values:

 

 

0

= Normal

 

 

1

= No ERROR

 

 

2

= No Strap or ERROR

 

 

Factory setting is Normal.

 

 

 

 

S85

Fast Disconnect

Configure\Edit\Line Dialer

 

Register allows the modem to disconnect immediately after receiving a

 

 

disconnect command from a local DTE or its own diagnostic control

 

 

panel.

 

 

Register has the following values:

 

 

0

= Disable

 

 

1

= Enable

 

 

Factory setting is Disable.

 

 

 

 

 