Test Branch

Figure 8-6. End-to-End Pattern Test

To access Pattern from the Test branch, make the following selections:

Test

:

>

Pattern

 

F1

F2

F3

Press the key until Pattern appears. Select Pattern to start this test.

Test

: Pattern

>

Blks Errd = xxxxxxx

F1

F2

F3

BlksErrd=xxxxxxx displays the number of blocks of data found in error (block size is 1000 bits per block). The message NoSync can appear as a value for BlksErrd while the modem's receiver is synchronizing. The message OvrFlw can appear as the value for BlksErrd if the counter overflows.

Press the key to display BlksRcvd=xxxxxxx, number of blocks of data received.

The Pattern test can be exited and reentered without restarting the test. The BlksErrd and BlksRcvd continue counting.

If the Test Timeout configuration option is enabled,

Test Timeout appears at the conclusion of the test. If it is disabled, the test operates until aborted. For more information on the Test Timeout configuration option, refer to the Tests section of Chapter 9.

To exit this function and remain in the Test branch,

press the key. To exit and return to the Top-Level

menu, press the key.

AT Command Equivalent

The AT command for Pattern is &T2.

3810-A2-GB30-20

November 1996

8-7