Image 97

Configure Branch

Table 9-6

(2 of 6)

V.42/MNP/Buffer Configuration Options

*Err Contrl Mode (cont.)

Direct Mode ± Modem connects at a data rate equal to or less than the initial DTE interface rate. (The modem never connects at a data rate greater than the initial DTE rate.) If the modem connects at a data rate lower than the DTE rate, the DTE must then adjust its data rate to equal the modem rate. Ultimately, the modem speed and DTE speed must be the same. Direct mode does not support error control or data buffering.

LAPM or Disconnect ± Modem attempts to connect in V.42 Link Access Procedure for Modems (LAPM) error control mode. If this fails, the modem attempts to connect in MNP mode. If this fails, the modem disconnects. This setting should be used for cellular connections (at both the mobile and PSTN sides) when it is known that both sides support V.42.

LAPM or Buffer ± Modem attempts to connect in V.42 LAPM error control mode. If this fails, the modem attempts to connect in MNP mode. If this fails, the modem connects in Buffer mode and continues operation.

NOTE: The modem must be reconfigured for Direct mode before changing the leased-line modulation if V.42 error control or Buffer mode are enabled with V.32bis on leased lines.

For Async Dial and UNIX Dial, V42/MNPorBfr is the factory default.

For Sync Dial and Sync Leased, DirectMode is the factory default.

AT command for Buffer Mode is \N0.

AT command for Direct Mode is \N1.

AT command for MNP or Disconnect is \N2.

AT command for MNP or Buffer is \N3.

AT command for V42/MNP or Disconnect is \N4.

AT command for V42/MNP or Buffer is \N5.

AT Command for LAPM or Disconnect is \N6.

AT Command for LAPM or Buffer is \N7.

*V42bis Compress: Enable

Nxt Enable Disable

V.42bis Compression. Enables or disables V.42bis data compression.

Enable ± Data compression operates in both the transmit and receive directions. This is the recommended setting for all applications.

Disable ± V.42bis data compression is disabled. This is rarely needed because V.42bis data compression does not cause data expansion for compressed data.

The factory default is Enable.

NOTE: This configuration option is only available if Error Control Mode configuration option is set for V42/MNPorBfr or V42/MNPorDsc.

AT command for Disable is H0.

AT commands for Enable are H1, H2, or H3.

*MNP5 Compress: Enable

Nxt Enable Disable

MNP5 Compression. Determines if the modem uses MNP Class 5 data compression. It can be set independently of V.42bis data compression. Online changes do not take effect until a disconnect occurs.

The factory default is Enable.

NOTE: This configuration option is only available if Error Control Mode configuration option is set for V42/MNPorBfr, V42/MNPorDsc, MNP or Buffr, or MNP or Disc.

AT command for Disable is %C0.

AT command for Enable is %C1.

*This configuration option is only available if Async/Sync Mode is configured for Async. Refer to the DTE Interface configuration options group for more on Async/Sync Mode.