COMSPHERE 3800 Series Modems

EditPasswdTable

The Password Table is the modem's security database. It contains all essential information for each password stored in the modem's nonvolatile memory. The information associated with each password is known as a record. Records are identified by an index which is a numeric name for a single record. A password's record is retrieved by entering its index.

The Edit Password Table group allows you to view and/or change the modem's security database table. To do this, you must retrieve a password's records by selecting its index (as described below).

The Edit Password Table group consists of the following options: Select Index, Password Type, Edit Password, and Save Edit.

To access EditPasswdTable from Set Access Ctrl, make the following selections:

Set

Access Ctrl

>

Edit PassWd Table

 

F1

F2

F3

Select EditPassWdTable.

Select Index

Select Index allows a specific record to be retrieved. Index addresses range from 0001 to 0020 for the Model 3810 and Model 3820 and from 0001 to 3000 for the Model 3811. The contents of this record can be viewed, edited, and saved.

To access Select Index, make the following selections:

Set

Access Ctrl

>

Edit PassWd Table

 

F1

F2

F3

Select EditPassWdTable.

Select Index

Ent￿ ￿" 0001

F1 F2 F3

Select Index appears.

Press the F2 (") key to increment index values.

Press the key to move the cursor to the next position.

Continue this sequence until the desired index appears, and then press Ent.

If an index outside of the range is entered, the message Index Too Big appears. Choose an index from the database's current index range.

After selecting an index, the Edit Password Table group's options (Password Type, Edit Password, and Save Edit?) appear in a series of LCD displays.

Keep the following in mind when scrolling down Edit Password Table:

The current function and index are displayed on the LCD's top line.

The LCD's bottom line displays Nxt and all selections available for the displayed security option.

Nxt indicates that more options are available by scrolling down. It also indicates that the value displayed on the LCD is the current setting.

Use the and keys to move selections into view.

Use the F2 and F3 keys to choose selections.

If no changes have been made, and the key is pressed, the LCD returns to the Top-Level menu.

If changes have been made, and the or key is pressed, then Save Edit? appears on the LCD.

Table 12-1 describes the settings of the Edit Table Password group options.

12-6

November 1996

3810-A2-GB30-20

Page 124
Image 124
Paradyne 3810 manual EditPasswdTable, Select Index Ent