COMSPHERE 3800 Series Modems

Table 14-2

(1 of 11)

3800 Series S-Registers

S-Register

Description

Front Panel Branch

 

 

 

S0

Auto-Answer Ring Number

Configure\Edit\Line Dialer

 

Register determines number of rings the modem will count before

 

 

automatically answering a call.

 

 

Enter zero (0) if you do not want the modem to automatically answer any

 

 

calls. Otherwise, enter a value from 1 to 255 for the number of rings to

 

 

count before answering.

 

 

Factory setting is 1.

 

 

 

 

S2

AT Escape Character

Configure\Edit\DTE Dialer

 

Register determines ASCII value used for escape sequence to enter

 

 

Command mode from Data mode.

 

 

Enter a value from 1 to 127 for the escape character. Any value greater

 

 

than 127 causes the modem to disable the escape sequence. When the

 

 

escape sequence is disabled, the modem cannot return to Command

 

 

mode until the call is disconnected.

 

 

Factory setting is 43 (+ key).

 

 

 

 

S3

Carriage Return Character

Configure\Edit\DTE Dialer

 

Register determines ASCII value used as the carriage return (Return

 

 

key). This character is used to end command lines and result codes.

 

 

Enter a value from 0 to 127 for the command end character.

 

 

Factory setting is 13 (carriage return key).

 

 

NOTE: The &W command used to save this change must be on a

 

 

separate line. This ensures both that the change is intentional,

 

 

and that the DTE can enter the new character.

 

 

 

 

S4

Line Feed Character

Configure\Edit\DTE Dialer

 

Register determines ASCII value used as the line feed character.

 

 

Enter a value from 0 to 127 for the line feed character.

 

 

Factory setting is 10 (ASCII carriage return or line feed).

 

 

 

 

S5

Backspace Character

Configure\Edit\DTE Dialer

 

Register determines ASCII value used as the backspace (Backspace

 

 

key). This character moves the cursor to the left and erases the previous

 

 

character.

 

 

Enter a value from 0 to 127.

 

 

Factory setting is 08 (backspace key).

 

 

 

 

S6

Blind Dial Pause

Configure\Edit\Line Dialer

 

Register determines how long (in seconds) the modem waits after going

 

 

off-hook before dialing a telephone number if using result code X0, X1,

 

 

or X3.

 

 

Enter a value from 2 to 255 seconds.

 

 

Factory setting is 2 seconds.

 

 

 

 

S7

No Answer Timeout

Configure\Edit\Line Dialer

 

Register determines how long (in seconds) an originating modem waits

 

 

before abandoning a call when no answer tone is received.

 

 

Enter a value from 1 to 255 seconds.

 

 

Factory setting is 45 seconds.

 

 

 

 