Configure Branch

Table 9-5

(3 of 5)

Leased Line Configuration Options

BdLn Auto Orig: Disable

Nxt Disable Enable FastBackup 2_min 5_min 10_min

Bad Lines Auto Originate. Allows the modem to dial the number stored in directory location 1 to restore communications with the remote modem when the leased lines fail.

This configuration option must be enabled in both the local and remote modem. The Answer mode modem must have its Auto-Answer Ring Number configuration option enabled. Refer to the Line Dialer configuration option group for information regarding Auto-Answer.

Disable ± The modem will not perform a Bad Lines Auto Originate.

Enable ± The modem will originate a call after 30 seconds of continuous bad-line conditions.

FastBackup ± The modem will originate a call after 20 seconds of continuous bad-line conditions.

2_min ± The modem will originate a call after 2 minutes of continuous bad-line conditions.

5_min ± The modem will originate a call after 5 minutes of continuous bad-line conditions.

10_min ± The modem will originate a call after 10 minutes of continuous bad-line conditions.

This configuration option is not available on the Model 3820.

The factory default is Disable.

AT command is S-register S46 = n :

S46

= 0

Disable

 

S46

= 1

30 Seconds

S46

= 2

20 Seconds

S46

= 3

60 Seconds

S46

= 4

90 Seconds

S46

= 5

120 Seconds

S

 

S

S

S

 

S

S

S46

= 21

600 Seconds

Note that the effect of S46 = 2 is out of sequence with the other values.

3810-A2-GB30-20

November 1996

9-31

Page 93
Image 93
Paradyne 3810 manual S46