Result Codes B

Table B-1

(1 of 2)

Result Codes

Numbers (1)

Numbers (2)

Word

Description

 

 

 

 

0

0

OK

Command executed

 

 

 

 

1

1

CONNECT

Modem connected to line

 

 

 

 

2

2

RING

Modem receiving a ring voltage from the VF line

 

 

 

 

3

3

NO CARRIER

Modem lost or does not detect carrier signal, or does

 

 

 

not detect answer tone

 

 

 

 

4

4

ERROR

Invalid command

 

 

 

 

5

5

CONNECT 1200*

Connection at 1200 bps

 

 

 

 

6

6

NO DIALTONE*

No dial tone detected

 

 

 

 

7

7

BUSY*

Busy or trunk busy signal detected

 

 

 

 

8

8

NO ANSWER*

No ``quietº answer (@)

 

 

 

 

10

10

CONNECT 2400*

Connection at 2400 bps

 

 

 

 

11

11

CONNECT 4800*

Connection at 4800 bps

 

 

 

 

12

12

CONNECT 9600*

Connection at 9600 bps

 

 

 

 

13

16

CONNECT 12000*

Connection at 12,000 bps

 

 

 

 

14

13

CONNECT 14400*

Connection at 14,400 bps

 

 

 

 

15

14

CONNECT 19200**

Connection at 19,200 bps

 

 

 

 

16

15

CONNECT 7200*

Connection at 7200 bps

 

 

 

 

17

17

CONNECT 16800*

Connection at 16,800 bps

 

 

 

 

19

1

CONNECT 300*

Connection at 300 bps

 

 

 

 

20

10

CONNECT 2400/ EC***

Connection at 2400 bps with error control

 

 

 

 

*Appears when the Extended Result Codes configuration option is enabled.

** Appears when the Extended Result Codes configuration option is set for Use_DTE_Rate. This displays the DTE data rate instead of the line rate.

*** Appears when the Extended Result Codes configuration option is set for Add/EC. If this configuration option is set for Add/V42, MNP, then either V42b, V42, MNP5, MNP4, MNP3, MNP2, or NoEC appears.

3810-A2-GB30-20