Cannot PING The Printer

273

AS/400 Troubleshooting

Use this section to resolve problems configuring AS/400 on TCP/IP 

networks.

Cannot PING The Printer

If you have problems trying to 

ping

 the printer:

•

Verify the configuration of AS/400, including the printer and any 

intervening devices such as routers and bridges.

•

Verify that the AS/400 line description is varied on and the 

printer is turned on and displays a status of ONLINE.

•

Verify that the AS/400 TCP/IP interface is active.

PSF/400 Terminates When Initialized

If PSF/400 terminates when you initialize it for IPDS printing and 

issues message PQT3603, check for the following error codes:

•

Code 10 means an incorrect 

RMTSYS

 or 

RMTLOCNAME

 (V3R2, 

V3R7, or V4R1) has been specified for the printer.

•

Code 15 means that PSF/400 timed out waiting for the printer’s 

response. Check the value you entered for Activation Timer 

when using 

WRKAFP2

, 

CRTPSFCFG

 (V3R2), or 

CRTDEVPRT

 

(V3R7 or V4R1).

•

Codes 20-39 indicate a general communications failure. Make 

sure all of the components in your network are operational, 

such as routers. If necessary, call Printronix technical support.

•

Codes 40-59 indicate a logic error between PSF and the printer 

control unit. Contact Printronix technical support.

Page 273
Image 273
Open full-size image