Plot, Odd Dot (P-Series Normal Density Graphics)

 

ASCII

Hex

Decimal

P-Series

ENQ

05

05

 

SFCC e

SFCC 65

SFCC 101

Serial

N/A

N/A

N/A

Purpose

Prints dots at the odd numbered dot columns.

 

Comment

This is the P-Series programming normal density graphics control code. The

 

ENQ code should occur before any printable data in the data stream. For high

 

density graphics, the Even Dot Plot code (04 hex) must be used in conjunction

 

with (and precede) the Odd Dot Plot code. Refer to the P-Series Compatible

 

Plot Mode section in the Graphics chapter for detailed plot mode informaF

 

tion.

 

 

Example

Print two normal density plot boxes using odd dot plot. Compare the odd dot

 

plot example below to the high density Even Dot Plot example on page 6-55.

6-56

Programming

Page 154
Image 154
Printronix P9000 Series manual Plot, Odd Dot P-Series Normal Density Graphics, Tion Example