CHAPTER 7
INTERFACES
Introduction
The P9012 printer is equipped with resident parallel and serial interfaces. Only one interface can be enabled at a time via the control panel. An optional Dataproducts Long Lines Adapter is available and replaces the Dataproducts and Centronics interface capability. Other optional interfaces include an Intelligent Graphics Processor,
This chapter describes:
nDataproducts Parallel Interface
nCentronics Parallel Interface
nAlternate Terminating Resistors
n
Dataproducts Parallel Interface
This interface allows the printer to operate with controllers designed for Dataproducts printF ers using a
Dataproducts Interface Signals
Table
Ready Line - A high true signal from the printer indicating AC power and DC voltages are present, paper is loaded properly, and the printer is not in a fault condition.
On Line - A high true signal from the printer indicating the Ready Line is true and the ON LINE switch on the control panel has been activated. The printer is ready to accept data from the host.
Data Request - A high true signal from the printer to synchronize host data transmission with printer timing. This signal goes true when the printer is ready to receive data. It changes to the false state shortly after the leading edge of the data strobe signal.