Line Spacing 1/6 Inch

 

ASCII

Hex

Decimal

P-Series

SFCC LPI;n

 

 

 

SFCC 2

SFCC 32

SFCC 50

Serial

ESC 2

1B 32

27 50

Purpose

Sets line spacing to 6 lpi or as set by ESC A.

 

Comment

The value of n can be 6 or 8 only. In LPI mode using P-Series printer protoF

 

col, if n = 6, this command sets line spacing to 1/6 inch. Values of n other than

6 or 8 will cause an error message (Command Line Error Messages are listed on page 6-3).

SFCC/ESC 2 asserts n/72-inch line spacing as set by SFCC/ESC A (page 6-52). If no distance has been set by SFCC/ESC A, the distance is 1/6 inch.

The control code line spacing selection will override the control panel line spacing setting.

Example The following example illustrates 1/6-inch line spacing and assumes that a distance has not been set by ESC A.

6-48

Programming

Page 146
Image 146
Printronix P9000 Series manual Line Spacing 1/6 Inch, Sfcc