APPENDIX F

HARDWARE JUMPER CONFIGURATION

Jumpers on the DCU (Data Control Unit) board are used to select a few configuration paF rameters. These jumpers are installed for normal operation at the factory. However, certain applications may require a modification to the jumper configuration. To change any of these configuration jumpers, the DCU logic board must be removed. Table F-1 describes the jumpF er configurations. To gain access to the DCU Printed Circuit Board Assembly (PCBA), the right side panel and the card cage access panel must be removed as described in the following procedures.

- CAUTION -

Some configurations require cutting an etch and soldering on the PCBA. These changes should only be performed by a trained technician.

- VORSICHT -

Manche Konfigurationen benötigen einen Ätzschnitt und Löten am PCBA. Diese Änderungen sollten nur von einem geschulten Techniker vorgenommen werden.

Table F-1. Hardware Jumper Configuration

Jumper

 

Description

Description

 

 

E1A-E1B

Print Head Select 0

E2A-E2B

Print Head Select 1

E3A-E3B

RXCLK Input

E3B-E3C

Clock to 68901 RC Input

E4A-E4B

TXCLK Input

E4B-E4C

Timer C Output to Clock

E5A-E5B

NTXCLK Input

E5B-E5C

Clock to 68901 TC Input

E6A-E6B

Clock DPMC Phase 1

E6B-E6C

Clock DPMC Phase 2*

E7A-E7B

Clock CPU*

 

*Normal Installed Jumpers

 

 

*NOTE: Only one of the Serial Interface clocks can be selected by inserting the related jumper. Selecting one of these clocks will require cutting the appropriate etch on the PCBA: For jumper E4A-E4B, cut E4B-E4C; for jumper E5A-E5B, cut E5B-E5C; for jumper E6A-E6B, cut E6B-E6C. These changes should only be performed by a qualified technician.