Ricoh AP3800C operating instructions Do not touch inside of the Fus- ing Unit

Models: AP3800C

1 124
Download 124 pages 63.07 Kb
Page 30
Image 30
Manual background

Replacing Consumables and Maintenance Kit

G Holding the green handle, pull up the Fusing Unit slowly in the direction of the arrow, and then put it in a stable and level place.

1

ZDJH208J

H Take out the new Fusing Unit from the bag and put it in a stable and level place.

Manual backgroundImportant

The A3 paper which comes with the new Fusing Unit will be

used in a later step T, so be care- ful not to lose it.

Do not turn the blue dial at the side of the new fusing unit when replacing it or before turning on the power switch.

I Remove the Fuser Oil Unit in the direction of the arrow.

ZDJH052E

Manual backgroundImportant

Do not touch inside of the Fus- ing Unit.

Be careful not to touch the oil.

J Match (U) on the front of the Fus- er Oil Unit and the arrow on the Fusing Unit as shown in the illus- tration.

ZDJH055J

Manual backgroundImportant

Be careful not to get oil on the metal point of the left side of the Fuser Oil Unit.

K Insert the left and right protru- sions of the Fuser Oil Unit into the white holders of the Fusing Unit (A), and then move the Fus- er Oil Unit in the direction shown by the arrow (B) to attach the Fus- er Oil Unit to the Fusing Unit.

ZDJH054J

L Put the removed Fuser Oil Unit in the bag that enclosed the new Fusing Unit, and then seal it.