Ricoh AP3800C Cannot Adjust See User’s Guide, Fuser Adjust At Unit Replace, Test Sheet Print

Models: AP3800C

1 124
Download 124 pages 63.07 Kb
Page 46
Image 46
Cannot Adjust

Cleaning and Adjusting the Printer

Fuser Adjust:Important

When the toner cartridge is al- most empty or "Auto Adjust” is not finished, the following mes- sage appears on the panel dis- play and Fuser Adjust is not available.

2

Cannot Adjust

See User’s Guide

Confirm that the toner cartridge is installed. The toner cartridge must be installed. See p.3 “Replacing the Toner Cartridge”.

If the toner cartridge is installed, perform "Auto Adjust". See p.34 “Auto Adjust”.

E Press {U} or {T} to display "At Unit Replace", and then press {En- ter}.

Fuser Adjust:

At Unit Replace

F Confirm that "Print" is displayed on the menu for printing the test sheet, and then press {Enter}.

H Check the test sheets and select the correction value for A through H.

Select "1", if black and magenta square overlap sharply and you can see white slits as the sample.

Select "0", if black and magenta square do not overlap sharply and you can not see white slits clearly.

A B C D E F G H 0 0 0 0 0 0 0 0

Press {U} or {T} to select "0" or "1" as the values for A - H. Press {En- ter} to move to the next letter. After setting the value for "H", press {En- ter} and the printer returns to "At Unit Replace".

Test Sheet:Invalid Value Note

If you select "0" for each alpha- bets or an invalid value is select- ed, an error m essage is displayed and the printer re- turns to "At Unit Replace". In this case, try again from step E.

Test Sheet:

Print

The following message appears on the panel display.

Set Sheet in

Bypass, then #

G Confirm that the A3 paper which comes with the Fusing Unit is in the Bypass Tray, and then press {Enter}.

The printer prints 8 Test Sheet (A -

H). For details about Test Sheet, see p.41 “Test Sheet Samples”

Invalid Value

Cannot Adjust

I Press {On Line}.

"Ready " appears on the panel dis- play.

Ready

36

Page 46
Image 46
Ricoh AP3800C Cannot Adjust See User’s Guide, Fuser Adjust At Unit Replace, Test Sheet Print, Invalid Value Cannot Adjust