System integration 7.3 Bearings

Note

For more installation examples, see "Motor assembly".

7.3Bearings

Selecting the bearing

1FW6 torque motors are built-in motors for direct rotary or swivel axes. To set up a complete drive unit, a bearing between the stator and rotor is required in addition to the phase-angle encoder system.

Your choice of bearing is governed by the following factors:

Geometric requirements (internal and external diameter)

Speed

Load (magnitude, direction)

Rigidity (accuracy, pretension)

Service life

The bearing is not included in the scope of supply.

WARNING

Bearing currents and static charging of the rotor:

Depending on the design and properties of the bearing, the rotor may become statically charged.

Measures must be taken to prevent this (e.g. insulated bearing design or grounding).

Note

Radial forces are generated between the stator and rotor. These must be taken into account when you select the bearing (see also "Motor assembly)".

1FW6 Built-in torque motors

111

Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7