Siemens 611 configurationmanual Technical data Symbol Unit, 1FW6190 Boundary conditions

Models: 611

1 324
Download 324 pages 4.89 Kb
Page 253
Image 253

Technical data and characteristics 14.2 Data sheets and diagrams

Technical data

Symbol

Unit

-xxB07-1Jxx

-xxB07-2Jxx

-xxB07-5Gxx

1FW6190

 

 

 

 

 

Data for precision motor cooler *)

 

 

 

 

 

 

 

 

 

 

 

Maximum dissipated thermal power

QP,MAX

kW

0.359

0.359

0.359

Recommended minimum volume flow

P,MIN

l/min

2

2

2

Temperature increase of the coolant

ΔTP

K

2.5

2.5

2.5

Pressure drop

ΔpH

bar

0.6

0.6

0.6

*) Parallel connection of main and precision motor cooler

 

 

 

 

Table 14- 24 1FW6190-xxB07-8Fxx

 

 

 

 

 

 

 

 

 

 

 

Technical data

Symbol

Unit

-xxB07-8Fxx

 

 

1FW6190

 

 

 

 

 

Boundary conditions

 

 

 

 

 

DC link voltages

UZK

V

600

 

 

Water cooling inlet temperature

TVORL

°C

35

 

 

Rated temperature of winding

TN

°C

130

 

 

Rated data

 

 

 

 

 

Rated torque

MN

Nm

704

 

 

Rated current

IN

A

56

 

 

Maximum speed at rated torque

nMAX,MN

rpm

390

 

 

Rated power dissipation

PV,N

kW

4.57

 

 

Limit data

 

 

 

 

 

Maximum torque

MMAX

Nm

1390

 

 

Maximum current

IMAX

A

130

 

 

Electric power of motor at MMAX

PEL,MAX

kW

46.3

 

 

Maximum speed at maximum torque

nMAX,MMAX

rpm

220

 

 

No-load speed

nMAX,0

rpm

540

 

 

Torque at n = 1 [rpm]

M0

Nm

941

 

 

Current at M0 and n = 1 [rpm]

I0

A

78

 

 

Thermal static torque

M0*

Nm

666

 

 

Thermal stall current

I0*

A

53

 

 

Physical constants

 

 

 

 

 

Torque constant at 20 °C

kT,20

Nm/A

12.6

 

 

Voltage constant

kE

V/(1000/min)

763.8

 

 

Motor constant at 20 °C

kM,20

Nm/(W)0.5

14.6

 

 

Thermal time constant

tTH

s

180

 

 

No. of pole pairs

p

-

42

 

 

Cogging torque

MCOG

Nm

4.7

 

 

Stator mass

mS

kg

41.2

 

 

Rotor mass

mL

kg

14.6

 

 

1FW6 Built-in torque motors

 

 

 

 

253

Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7

 

 

 

 

Page 253
Image 253
Siemens 611 configurationmanual Technical data Symbol Unit, 1FW6190 Boundary conditions