Technical data and characteristics 14.2 Data sheets and diagrams

Technical data

Symbol

Unit

-xxB05-1Jxx

-xxB05-2Jxx

-xxB05-5Gxx

1FW6160

 

 

 

 

 

Temperature increase of the coolant

ΔTH

K

8

8

8.1

Pressure drop

ΔpH

bar

0.3

0.3

0.3

Data for precision motor cooler *)

 

 

 

 

 

Maximum dissipated thermal power

QP,MAX

kW

0.23

0.231

0.233

Recommended minimum volume flow rate

P,MIN

l/min

1.5

1.5

1.5

Temperature increase of the coolant

ΔTP

K

2.3

2.3

2.3

Pressure drop

ΔpP

bar

0.3

0.3

0.3

*) Parallel connection of main and precision motor cooler

1FW6 Built-in torque motors

229

Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7

Page 229
Image 229
Siemens 611 configurationmanual Data for precision motor cooler, Δt P